Minor Releases
3.2.15.7314
- Allow tuning parameters to be manually changed during a run if an engineer license is installed
- Configure which task fields are included in reports and their order
- Monitor a connected system for idle state to trigger conditional automatic functionality
- Automatically switch species from SO2, CO or MeCl to CO2 after 30 minutes of the system being idle (configurable)
- Be able to reorder linearity target beam value within the linearity method parameter collection editor
- Dashboard zoom and scroll bar state is now saved as part of the system layout
- Method notification dialog blocks no longer disable the connected system window when shown
- Ensure that the error message dialog does not exceed an initial maximum height
- Further improvements to export readbacks utility
- Ensure that changes to the data processing ratio settings are reflected in the batch grid columns
- Other bug fixes
3.2.14.7265
- Improve the exports of readbacks to ensure that they are in the correct order
- Improve firmware update tool
- Fix calculated column formatting issue
- GC method editor (XML view) now displays relevant documentation for node attributes
3.2.13.7246
- Be able to define standards as "Drift Correction Standards" for use by the Drift Correction Wizard
- Be able to clear any applied corrections from within the Corrections Wizard
- GC calculated columns can now automatically be applied to all reported compounds by leaving the "Peak Id" blank for variable declarations
- Fix tasks sometimes loading in the wrong order in a Task List
- Fix display issue when using multiple monitors
3.2.12.7221
- Fix issue where updated centrION monitoring gas pressure is not saved when switching species
3.2.11.7211
3.2.10.7209
- Fix display format of Atom % results
- Be able to display the Peak Library after closing it within a GC batch
3.2.9.7197
- Edit peak options should prioritize the selected peak over any unidentified peak under the mouse
3.2.8.7184
- Improve language pack editor to show default evaluated translation next to the English version
- Be able to customize the directory where all IonOS data is stored
3.2.7.7178
- Added the option to not acquire GC FID data
- Fix GC status message not being removed
- Ensure that iso FLOW panels are visible to all precisION users
- H3 correction method should restore the monitoring gas beam height after completion
- Allow all users to run the export readbacks utility
- Be able to paste a single column of values directly into selected tasks within the task list
- Update the IonOS installer to show terms and conditions
- Update the IonOS installer so that the installation path is customizable
- Fix issue with recognized designer item blocks for some users
3.2.6.7140
- Fix dashboard bindings with string format
- Include centrION schematic for use by Engineers
- Extend method workflow parameter entry to provide valid values via the right click context menu
- Improve dashboard and method workflow connection path finding algorithm
- Ensure dashboard rubber band selection works correctly
- Fix intermittent IonOS freeze issue resulting from available automatic updates
3.2.5.7100
- Highlight activated panels within the connected system and data processing windows.
- Ensure that new panels (that have not been displayed before) either display in a predefined location or over the currently active panel
- Ensure that the GC batch processing comparison view displays as a floating window by default
- Dashboards Schematics - be able to define connection thickness and if the line should appear as dashed
- Fix acquisition data view right click context menu to detect peak relevant to the menu for multi-species displays.
- Fix recursive (self referencing) method workflow designer validation
3.2.4.7092
- Modify iso FLOW Carbonates method to go to the catch pot on finish and abort
3.2.3.7087
- Fix "Stability (Auto Stop)" method
3.2.2.7085
- Ensure that connection arrows and labels appear correctly on load of the Method Workflow and Dashboard designers
- Be able to modify the order of custom dashboards within a system
- Be able to filter the task list based on method categories
- Ionplus precisION specific changes (methods)
- Be able to specify the system type and reset appropriate methods visibility
- Add delay parameter before monitoring gas peaks to EA methods
- Fix incorrect centrION Beam Height message
- Fix dashboard multi-binding
- Ensure that dashboard schematic modeling is performed at load correctly
- Ensure that dashboard schematic modeling calculates connection colors correctly
3.2.1.7060
- Improve method editor validation
- Panels overview pane is only visible if the mouse is within the panel
- Application Menu -> View System Overview allows easy and quick access to the current system configuration and comprehensive real-time control / readbacks
- Be able to select individual columns within the data processing peak results for easy copying to clipboard
- Be able to choose if column headers are copied within the data processing peak results
- Improve Gilson Test Layout utility to allows changes to be discarded
- Update the Gilson layout editor to make it easier to see the operations per rack
- Gilson method validation now validates that an operation has the required number of steps
- Speed up method initialization after subsequent IonOS loads
- Fix incorrect MFC pressure warning messages
3.2.0.7047 (Initial Release)
Click here to see the release notes for the initial 3.2 release.